Smoke Vent Systems and Compatible Conventional Devices
Hello folks, Been on here a while but the first post so go easy! Just a wee bit background from me, I own and run Core Fire Limited in Glasgow. I have ran my own FP company for 4 years now and we cover...
View ArticleIntegration
Hi gentlemen I want to connect two panels together the first one is Notifier AFP-400 and the another one is C-TEC XFP 2 loop, So how I can do it and which module or interface will be suitable for this...
View ArticleFire 5 Upgrade
Hi Was wondering if any one had a sheet sheet for upgrading Morley fire 5 to fire 6 panels. I used to have one detailing the steps to take that would tell you if the loop cards were compatible with...
View ArticleAnyone know what panel this is?
Any ideas would be welcome. Thanks 20131206_100300.jpg (Size: 2.07 MB / Downloads: 20)
View ArticleFire Engineer Training
Hi everyone, I'm an engineer based in North West England and have been working on fire alarms ( SA, DA + CCTV) for more than 8 years now. With greater experience you find yourself sent to an...
View Article72hr standby addressable panels
I am looking for a panel that can do 72hr standby ranging from 5 loops to single loops. The protocal is apollo xp/ discovery and at the largest battery size being 64 ah based on current panels...
View Articlenewlec/bardic 4 zone panel jumper & fire relay
Does anybody know what the jumper on a newlec 4 zone panel does? I have a panel where the fire relays do not operate and I wondered if you needed this jumper connected for them to work. No manual I...
View ArticleMinerva MX4000 Power Supply Fault
Hello folks, Wondering if anyone can help? We have a Fault come up on a MX4000 panel "Mains Supply I/P" Anyone seen this, the PSU is giveing a slight buzzing noise. Cheers. Ryan.
View ArticleNotifier ID50 Adding Devices
Good evening folks, Wondering if anyone can help or who knows how to add devices on a Notifier ID50 Fire Panel. After doing some reading it looks like it maybe able to be done through the panel without...
View ArticleCQR- Firebrand FI-A Addressable Panel
[/size]Good day to all, still on call!!! Has anyone worked on the Firebrand FI-A Addressable Panel. I went to a call with a Supply Fault Yellow light showing (Green Power light on). Mains is there so...
View ArticleZiton/Photain Panel testing
have a Photain/ziton zp3 panel that only allows testing of one zone at a time is there a way to change this to test all zone at once as it is in a student village and each apartment is set up as a zone...
View ArticleC-tec AFP Software
Morning gents, just been trying to download the old AFP software for the old old panels, and it seems my laptop is too new for it. Anyone else had this problem??
View ArticleNewlec Panel
Hi Guys, Anybody any ideas if this Newlec panel is addressable or non-addressable & what the model number is? Ta Newlec Panel.jpg (Size: 78.09 KB / Downloads: 3)
View ArticleAMPAC FireFinder
Does anyone have the ConfigManager software for the above? As lng as it isn't copyrighted/licensed of course.....
View ArticleMX1000 obsolete or not date
HI Guys Would anyone know what date the MX1000 will be given its last rites? Its been Legacy for a while and just wondered when full support will be removed and they will start trying to sell...
View ArticleRemoving MCP's
Hi, If you install AFD to a communal area only of a block of flats and you blank of the MCP's how would you categorise the system? also is it viable to blank off the MCP as this would generate more...
View Articleadvanced mxp-034 programmable sounder card
Evening all. Just got a call from engineer on site struggling with one of these sounder cards. It's been a few years since I've had to put one in. I thought it was just 24aux supply and a signal in...
View ArticleKentec Panels
Hi all We have recently been installing a number of Kentec panels on our sites and have been purchasing these panels via our supplier rather than direct from Kentec, so i thought i would give the...
View ArticleKAC addressable MCP connectors
I took a client to court a two years ago, after he decided he didnt have the money to pay for a system, I had been installing. I won, and he had to pay up for the work done... however. On leaving the...
View Article