Anyone seen one of these?
Afternoon guys Anyone ever come across one of these - apparently connected to a honeywell panel?
View ArticleC tec mfp 4 zone into a 12
Anyone had any issues with the above panel? Updated 4zone to a 12 zone with 2 zone expanders Carrying out test all zone lights go into fault, then fire lights come on all zones then starts to go into...
View ArticleBeam Detector
Can anyone recommend a beam detector for a conventional system. Nothing fancy or too expensive. Thanks
View ArticleNotifier id2000 upload
just seeing if anyone would be interested in uploading info out of a the above panel in the city area. It's going to be changed out for another panel make so just need the cause and effect plus text...
View Article30 Minutes Fire Protection - Meter Box
Hi, Housing standards are requesting that the electric meters on an escape route are to be have 30 minutes fire protection, some of the meters are the keycard type of meter and require easy access...
View ArticleTyco MXC panel
Does anyone know if there is a direct replacement of the attached panel which is running 2wire tyco sounder bases or is upgrade time. 8590CF55-7467-4FB8-8FA9-78D5BFB8870A.jpeg (Size: 1.57 MB /...
View ArticleC-Tec CFP to CXP
Hi Folks, Looking for a little confirmation/advice I am looking at a current system that has a C-tec conventional system with 3 zones out of the 4 available on the panel in use the client wants to...
View ArticleBatteries 4 or 5 years?
How often do you change the standby batteries every 4 or 5 years? Also do you change them at the 4/5 year mark even if the still show good after testing?
View ArticleSmall repeater
UBaby fire alarm panel chassic creditied to CEL IMG_1669.JPG (Size: 1.31 MB / Downloads: 8)
View ArticleAll base sounders ?
Hey folks Just replaced couple of heads on a small family run seaside hotel i got sent too.....Haes Vector Addressable, Apollo protc (haven't touched much of those) It had no separate sounder circuit,...
View ArticleFike Twinflex Pro - FYI
A note of warning to suppliers & installers of these panels. Apologies if this has already been covered, first time i've come across it though. Commissioned one of these "panels" (8zone) the other...
View ArticleM1000? Panel ID
Anyone have an idea of what panel this is exactly. Been servicing it for a few years now with no problems, but would like to have a read up on it incase i need to do more than just isolate sounders,...
View ArticleMorley ZX5SE Software
Good evening guys, I've got a job to re-commission and re-text/zone a ZX5SE and connect an I/O for the dualcom. Never really used them before, but the software seems pretty intuitive. I've noticed when...
View ArticleKentec protocol
Hi Is it possible to change the protocol from Argus to Apollo without a return to Kentec . Bob
View ArticleNatalarms still going strong
This is one of the oldest panels I maintain and it's still going strong using cmos logic chips if anyone remembers them! IMG_1679.JPG (Size: 1.63 MB / Downloads: 1)
View ArticleZone isolators
Good Morning, We have just taken over a system from another company it is a single loop morley zx with Apollo devices. It is a high rise block and has a loop going up the cable riser with a zone...
View ArticleAlarmline II Analog linear heat
Hi guys, Has anyone here ever worked with these panels? Regards, J
View ArticleBi Wire conversion
Hi all. Has anyone had issues with changing from a non addressable convectional system to a Bi Wire?, It is a hotel that requires the sounder level to be increased and a few additional detectors in...
View Articletransparent fault on a morley zx5
we have a 2 panel morley network with master panel (1) and a slave panel (2) with a chiron communicator connected to slave panel 2. When the master panel 1 goes into fault the slave panel 2 sends a...
View ArticlePrinter rolls
evening chaps trivial question, but does anyone know the widths of printer rolls for advanced Mxpro5 internal printer (thermal) and Morley ZX5Se internal printer (I’m sure it’s ink not thermal). Need...