Sita 200 Plus
I have a Sita 200 panel in a block of flats I look after that is playing up continually. I am considering replacing it with a Fike Duonet so that the 30 detectors and call points can stay in place, I...
View ArticleAddressable Zeta Premier AL Fire alarmPanel
Got a 4 loop addressable Zeta Premier AL fire Alarm Panel, which loops had been programmed into Zone, found out that the terminals of loop 2,3 and 4 had been jumpered with cable. I do not understand...
View ArticleAddressable Zeta Premier AL Fire alarmPanel
Please house i need Zeta Addressable Premier AL Software, my client have a Zeta Addressable 4 loop Premier AL double Panel. Its urgent. Thanks
View ArticleZeta Premier AL 5-8 Loop Panel.
I have a panel; Zeta Premier AL 5-8 Loop addressable, when i try to use it try to Reconfigure a new loop, it is seen nothing, tried all the loop terminals, it is seen nothin,check connections all are...
View ArticleGent States
Guys, I always thought when changing the state of a Gent detector the timeblock on & the timeblock off state had to be entered. Went to a site today where only the timeblock on state had been...
View ArticleID 3000
Hi Ive got a site with a master slave set up. The customer wants 9 I/Os fitted to the PV control equipment, around the site, to shut down in the event of a fire. These 9 I/Os will be fitted to...
View ArticleHochiki loop tester
Just been offered a hochiki loop tester to use. I have the Apollo loop tester, and am ok using it. I am very open to hearing other folks experiences / tips on using the hochiki one..thanks (Yesterday...
View ArticleAdvanced loop card short circuit testing
My engineer carried out some short circuit loop testing on a 4 loop Advance MX4000 panel and blew up 3 loop cards, anybody else had similar problems?
View Articlevigilon config
we've had a contractor add an interface onto an old vigilon panel from about 1999. (usual gent s.i. process of changing an entire panel for £3k and trying to get it to work with the old panels on the...
View ArticleXP95 Zone Monitor Internal Fault
Hi Chaps I have just taken over a site with a Kentec Syncro with Xp95 detection in the landlord areas and zone monitors for each separate office. 1 zone monitor is showing an internal fault. Is this a...
View ArticleMZX Faults
Hello, at a customer of mine after moving the cabling and the panel from a room to another I get 2 faults. Loop s/c fault and Lnet data path flt. Any idea of what these might be? Thanks
View ArticleSquashni 2 wire sounder base – anyone got 2no ?
Hi Guys I have a client who needs 2no of the above. I know they are obsolete and they are on a Firesense Concept panel which is also obsolete but you never know......anyone have a couple they could...
View ArticleXp95 sounders and class change
Just completed a job with sounder beacons on a Morley, and once in a while a sounder will fail on class change usually AV 2 which I believe is the beacon. Is this a common problem?
View ArticleGent 34000 addressable screen blank
My Gent 34000 Addressable fire alarm screen went blank,could not read or see any message. Could it be the LCC card or the screen itself. Pls house help
View ArticleApollo Duct Detector IP Enclosure
Evening Chaps, Has anybody ever housed an Apollo duct detector in an IP rated enclosure? If so, where was the enclosure purchased from. Cheers
View ArticleGent Nano changing states
Hi, have a gent nano and seeing does anyone know if you can change the state of a device like the vigilon Am looking to change one but cannot see an option in the menu Thanks
View ArticleProtec Print Outs
Just been thumbing trough some print out's today, and never really took much notice to them previously, but can anybody shed some light on some of the meanings on them. Say on the loop allocation data...
View ArticleCCTV and Security
Need a little help, i know its a FA forum but we have just employed an experienced Security and CCTV Engineer and are now looking for Accreditation. Does anyone have a format quotation for CCTV and...
View Article