VesdaNET
Guys I have just finished a design for a large air sampling system within a distribution warehouse, I have 43 Vesda Panels all connected on a VesdaNET network (with Graphics) with another panel next to...
View ArticleIdentify these Devices
Guys I am looking to replace these devices that are currently in a casino in Brighton, they are running on a morley panel so have 2 questions 1 - What protocol are these (I think they are system...
View ArticlePower Supplies for FA panels
Power supply for FA panel :- Should it be primary and secondary (redundant) or Just the primary single source is enough (non - redundant)?.
View ArticleIdentify this fuse?
Evening guys Do anyone of you know the name or model number of this type of fuse. Its from a firesense panel (now discontinued) that client wont change? Thanks in advance [img][/img][/php]
View ArticleJuno 3000
I am having fun with this forum today... I need to add an I/O to this system . If I autolearn will I loose all info, I don't want to get that Kentec feeling. Cheers
View ArticlePreussag spares
Hi, we have a Preussag Fire & Gas panel on a Rolls Royce gas compressor package. We are currently desperate for spare common facility modules (P80620). I believe these are now obsolete and are no...
View ArticleNew post
Posting from my phone but I can't see text as I write it, I selected align left, my keyboard pops up and I'm typing !
View ArticleKAC callpoints on Rafiki Twinflex Checkpoint Plus
Does anyone know if the Rafiki Tewinflex Checkpoint Plus panel can be made to work with KAC call points (presumably twinwire of some other make) I didn't think so, but I've been to a site full of them...
View Articleminerva 80 relay test
I need to test a shutdown relay on a Minerva 80. I know it is possible to 'force point's to test a relay but ideally I would test fully without setting off other sounders, relays etc. Is it possible...
View ArticleSiemans Cerberus FC722
Hi everyone. Im working on one of these panels tomorrow doing a service and when i visited before i couldn't carry out a full service as i could not figure out how to disable the sounders/outputs....
View ArticleHi does anyone know this detector please?
Hi does anyone know this detector please? 20160330_104425crop.jpg (Size: 348.33 KB / Downloads: 5)
View ArticleZiton Device Label Change
Guys, I amended a MCP device label on a Ziton panel from the front end & saved it. I then tested the MCP which showed the updated label - all fine & dandy. When a second test was completed the...
View ArticleBattery Impedance Fault on Kentec Syncro AS Lite
Its good to see big progress has been made on the site Well done fellas! Anyway, I have an issue with a Kentec Syncro AS Lite which I thought I had cured last week, it keeps throwing up battery...
View ArticleGent 3260 upgrade
Evening guys Any advice on best course of action on the following system. A potential new client has asked us to quote for a bit of an upgrade. They are a large church and parish hall that has an old...
View Article