Kentec panel with keypad

I have a site with what is a early kentec panel with a keypad for access instead Of a keyswitch, kentec say they did not make a panel like this it's dated around 1998 looking like the kt3000...

View Article


Advanced - Zone Across Multiple Nodes

The following is a siuation i have not encountered before. Normally when we use multiple nodes its for different buildings. However, this time we have a building with six floors and a loop per floor....

View Article


Image may be NSFW.
Clik here to view.

Gent Vigilon

My client had a Gent Vigilon Panel 1-6 Loop, working . Then we started having faults like; (1)dialed aux relay2 psecond  (2)Commandbuild dialed  1-255 (3)Zone disabled (4)Master section disabled now 12...

View Article

Juno en54

Just at a site service, someone's has changed the engineers code so cannot access menus. It should be 3***7 can we gain access another way. I will ring kgm when they open , it's just I have to test it...

View Article

Any CEL Voyager guru's in the house?

Today. I attempted to get a download (or upload from panel ) of the information contained within a CEL Voyager which was badged up as an Emergilite something or other. I have a copy of FusionV2...

View Article


Install practice

Went to commission a system  installed by a NICEIC contractor. Plaster board ceilings, no conduit boxes or cavity boxes fitted so no glands for cable restraint. Had an almighty row with the contractor...

View Article

Electrical Contractors

I'm visiting a school today to survey for a new FA system, we are a 22 year old company with BAFE SP203 for six years, they have also gone to two electricians who are pricing the works.What should i...

View Article

Morley network

Have to go to a system early morning at a school. Shared zone system network with delay on all panels. Have been told the master panel signals out but not the slaves.  My question is would the fire...

View Article


Advanced MX Pro-4

Hi Guys Ive checked through the literature I have for the advanced MX Pro-4 panels and cant see what i need. Do the panels come standard with just a 20 zone LED display or are they different for the...

View Article


Kentec integral sounder mode

Lads just wondering has anyone set this type of setup on a large enough system ( 15 panels networked) They are student accommodation apartments so if a device activates in that apartment the sounder in...

View Article

Do all new installs have to use EN54?

Does all newly installed equipment have to be EN54 compliant or can 'new old stock' equipment certified to BS5839 still be used? Somebody I know asked an engineer this and he said that by complying...

View Article

advanced local terminal MXpro5

hi all, anyone know how to use local terminal with the mxpro5 with usb link?  I can see the panel in device manager but there is no comm port, am I missing something thanks

View Article

801PH replacement head

Hi all, I am having issues programming a new 801PH detector head onto my Minerva T2000R panel. I don't have a program tool and can remember doing it on the front panel last time I had a faulty one but...

View Article


Recommend Dialler please?

Hi we have a JSB Firedex 2204 conventional panel with an SD1+ speech dialler. All has been installed for about 8 years and has given faultless service. However, I would like to upgrade the dialler. I...

View Article

Photain duct probe

i have a client that needs to replace the above, is there an equivalent unit out there  My thoughts were to fit apollo one with psu and relay triggered from remote output I seem to remember a Swiss...

View Article


Protec 6300

Hi all I went to a site today that had a Protec panel to exchange some faulty devices but found that after i replaced them, the panel was not showing the codes for the new devices. Would this be as...

View Article

Advanced Software Manual

need some help here guys please, cant find a software manual on advanced site for toffee even when logged into 360. need to know what unaccepted condition is in the output group editior? or how to...

View Article


CEL Discovery

Can you change and add devices via the keypad and can someone please PM me theEngineer code,thanks.

View Article

EMS FIRECELL FALSE ALARMS

Hi All Has anyone experienced intermittent false alarms. I have a site and have false alarms in hallways and locked rooms. The detectors are spotless and not contaminated. Its a school but a lot of the...