Kentec panel with keypad
I have a site with what is a early kentec panel with a keypad for access instead Of a keyswitch, kentec say they did not make a panel like this it's dated around 1998 looking like the kt3000...
View ArticleAdvanced - Zone Across Multiple Nodes
The following is a siuation i have not encountered before. Normally when we use multiple nodes its for different buildings. However, this time we have a building with six floors and a loop per floor....
View ArticleGent Vigilon
My client had a Gent Vigilon Panel 1-6 Loop, working . Then we started having faults like; (1)dialed aux relay2 psecond (2)Commandbuild dialed 1-255 (3)Zone disabled (4)Master section disabled now 12...
View ArticleJuno en54
Just at a site service, someone's has changed the engineers code so cannot access menus. It should be 3***7 can we gain access another way. I will ring kgm when they open , it's just I have to test it...
View ArticleAny CEL Voyager guru's in the house?
Today. I attempted to get a download (or upload from panel ) of the information contained within a CEL Voyager which was badged up as an Emergilite something or other. I have a copy of FusionV2...
View ArticleInstall practice
Went to commission a system installed by a NICEIC contractor. Plaster board ceilings, no conduit boxes or cavity boxes fitted so no glands for cable restraint. Had an almighty row with the contractor...
View ArticleElectrical Contractors
I'm visiting a school today to survey for a new FA system, we are a 22 year old company with BAFE SP203 for six years, they have also gone to two electricians who are pricing the works.What should i...
View ArticleMorley network
Have to go to a system early morning at a school. Shared zone system network with delay on all panels. Have been told the master panel signals out but not the slaves. My question is would the fire...
View ArticleAdvanced MX Pro-4
Hi Guys Ive checked through the literature I have for the advanced MX Pro-4 panels and cant see what i need. Do the panels come standard with just a 20 zone LED display or are they different for the...
View ArticleKentec integral sounder mode
Lads just wondering has anyone set this type of setup on a large enough system ( 15 panels networked) They are student accommodation apartments so if a device activates in that apartment the sounder in...
View ArticleDo all new installs have to use EN54?
Does all newly installed equipment have to be EN54 compliant or can 'new old stock' equipment certified to BS5839 still be used? Somebody I know asked an engineer this and he said that by complying...
View Articleadvanced local terminal MXpro5
hi all, anyone know how to use local terminal with the mxpro5 with usb link? I can see the panel in device manager but there is no comm port, am I missing something thanks
View Article801PH replacement head
Hi all, I am having issues programming a new 801PH detector head onto my Minerva T2000R panel. I don't have a program tool and can remember doing it on the front panel last time I had a faulty one but...
View ArticleRecommend Dialler please?
Hi we have a JSB Firedex 2204 conventional panel with an SD1+ speech dialler. All has been installed for about 8 years and has given faultless service. However, I would like to upgrade the dialler. I...
View ArticlePhotain duct probe
i have a client that needs to replace the above, is there an equivalent unit out there My thoughts were to fit apollo one with psu and relay triggered from remote output I seem to remember a Swiss...
View ArticleProtec 6300
Hi all I went to a site today that had a Protec panel to exchange some faulty devices but found that after i replaced them, the panel was not showing the codes for the new devices. Would this be as...
View ArticleAdvanced Software Manual
need some help here guys please, cant find a software manual on advanced site for toffee even when logged into 360. need to know what unaccepted condition is in the output group editior? or how to...
View ArticleCEL Discovery
Can you change and add devices via the keypad and can someone please PM me theEngineer code,thanks.
View ArticleEMS FIRECELL FALSE ALARMS
Hi All Has anyone experienced intermittent false alarms. I have a site and have false alarms in hallways and locked rooms. The detectors are spotless and not contaminated. Its a school but a lot of the...
View ArticleName that panel
New day another new panel. Bragging rights to the first.... homebase carlow.jpg (Size: 1.74 MB / Downloads: 4)
View Article