Hi guys my laptop won't see zeta panel, zeta said I need to install some new usb driver onto my laptop and promised to email it but they haven't anyone know what driver they are referring too plz Cheers
View ArticleDry Riser
Can anyone advise a company that can service dry risers in the North East. PM me if you can help,thanks.
View ArticleMorley DXc 2
Hey guys, What colour should Apollo devices be blinking on a Morley DXc? One of the other hobbyists I know has one where all his isolators are blinking yellow (MCPs, sounder bases), and there's no...
View ArticleDin Rail Ceramic Connectors
We are relocating a FAP & need to extend all cabling (loops, bell ccts, network etc). We are installing a junction/marshalling box at the existing panel location. What would be the best method to...
View ArticleFitting smoke detectors to plasterboard ceilings
Hi all, what is the regulations with fitting smoke detectors to solid plasterboard ceilings, existing system has cables down through hole in ceiling, rawlplugs and screw to hole base in place. Is this...
View ArticleKentec - Remote PSU Advice Needed
Hi All... First Post with probably a very basic question.... but see Introduction and be gentle!!! ( I did as first point, contact Kentec tech help - and thought I understood what I was told, but...
View ArticleGent Nano change device type
Does anyone know if you can change the device type from the front of the panel
View ArticleApollo series 30
Hi all , will addressable Apollo series 30 addressable device work with a new advanced mx4 pro panel? I know the heads are really old and should be retired, trying to figure out if another company done...
View ArticleCabling Regs
Hi all I have a job to do this weekend where i need to add XP95 loop sounders onto an existing system, the loop runs through the lofts picking up detection and sounder bases, i would normally just...
View ArticleApollo xp95 heat detector issue
Hi , one of my colleagues called me with an unusual problem with an apollo xp95 heat detector on a Morley zx panel, he activated the heat detector with heat detector tester and the led lit up , system...
View ArticleClass change
Gentlemen. Can I set up an apollo input as a class change input. If so can someone tell me please. I also need to do the same on a Morley so if someone wouldn't mind sharing. No big deal either way....
View ArticleOutput short circuit fault
Another strange fault to solve , replaced an old panel with new Morley dx 1 loop panel, all new devices on loop working perfect after installing new Apollo devices on system. Bell loop 1 reading 6.8 k...
View ArticleNew Apollo loop tester
Hi Has anyone had any experience with the new Apollo loop tester, especially with locating an open circuit fault. Just curious to see if they are worth the money as I have a site with quite a large...
View ArticleMenvier AX1
Evening all, I have to carry out some routine maintenance on a menvier ax1 panel tomorrow. I was just wondering if anyone has a manual for one or if they can tell me how to put the panel in walk test...
View ArticleVERY LOW (-42C) CABINET FIRE DETECTION
Hi, can You recommend me conventional type (or C/NO contact output) detector for cabinet fire detection system where the standard operational temperarure is around minus 42 Celsius degree and the...
View ArticleMorley DXC Software
Evening All Long shot and a big ask, would anyone have the Morley DX connexion fire panel software, I thought I had it on a disk but it appears I only have ZX and DX dimension. Cheers Paul 07766057191
View ArticleApollo xp95 sounder base faulty
Hi all , I had 4 faulty addressable xp95 base sounders today , added them to a working Morley dxC 1 loop panel , it would not see the base sounders or the smoke detector on it. It also lost some...
View Article2 wire ADT system.
Morning, We have an ADT 2-wire fire system. We have a new out building that requires a sounder and flashing lighting to give warning that the fire alarm is going off. ADT say that they no longer made...
View ArticleZP3
Anyone know what the boot up, test, maintain & code links are for please? BC7F46D8-4C7A-46FB-8864-A95DBFED07A2.jpeg (Size: 751.26 KB / Downloads: 1)
View Articlenon-combustible , yet non-metallic fixings!?
right we have an ems/kentec wireless system with some problems. the large network communicator aerial (to the repeater panels) has a coaxial data cable which I have just realised is held in place by...