Morley Connexion Network issue
Hi All, Has anyone ever had a “Status Mismatch” fault on the above panel? My engineer went to a site today (new customer) to install a couple of I/O’s on the Loop (Apollo). There are two panels...
View Articleapollo 2nd loop sounders silent
added a second loop to a cel discovery panel which at the moment simply has 2 xp95 sounder beacons and 2 discovery heads loop 1 sounders all go off fine in a full test, loop 2 is silent apart from 1...
View ArticleSmoke pens
I need a new smoke pen for testing aspirating systems. Any recommendations please. Cheers
View ArticleZeta Addressable simplicity Panel: change fault.
Fault on 2 loops zeta simplicity addressable Panel, loop 1 showing faults. On the panel screen shows the device no. and flashes change. Please house, how do I solve these problems, all devices on loop...
View Article7 causes for false alarm of fire detectors
Smoke detector, gas detector, heat detector, CO detector and compound detectors are used in fire alarm system. But false alarm caused by these detectors also led to serious loss. The worst is, false...
View ArticleApollo XP95 Addressing
Hey Guys Can I just confirm the following please . I/O unit addressed as normal. Break glass , Loop Sounder and Sounder bases are inverted when addressed. Cheers
View ArticleZeta Premier 4-Loop panel config and software
Hello all, I am facing some issues with a Zeta Premier AL. The installation is pre-existing, I have no file of the panel and I need to get the whole configuration from it. I use GLT Premier AL Design...
View ArticleUsing hyperterminal to view Gent output
Hi All, Hoping someone can help. Have a little project on the go where we need the printer output into hyperterminal from a Compact panel. We are doing this via RS232 and have used virtually very...
View ArticleHochiki CHQ-WSB2
Hi guys, Sorry to ask simple questions but does anyone know whether the CHQ-WSB2 sounders are marked down as a YBO-BSB or a CHQ-WSB in the Advanced software? Have forgotten and something's making me...
View ArticleNotifier
Hello! I need to swap a Notifier AM2000 to another panel, the choice should be an ID3000, but it is a bit expensive... What i need to now, please... is if there is another panel that can work with...
View Article55000-741 apollo VAD and morley panels
Does anyone know whether apollo 55000-741 VAD devices are compatible with morley dxc/zxe panels? Morley say 'I think so!" but that part number does not show up in my morley zx software (v6.20).
View ArticleFireline MAG Pro - Software & UDL Lead
Morning fellas Anyone worked on one of there horrid things before? Its fitted in an apartment block and it looks like it has never been commissioned. Everything on zone 1 and no location text...
View ArticleCO Detection
Im looking for a CO detector , must be 12-24vdc with fire and fault ouputs, its going to be installed on a Hochiki loop using a POM.
View ArticleExtinguishant Control panel Solenoid out
Dear All, do You have information about any solenoid "distributor box or module" available on EU market, where we can connect to input of this device to the solenoid output from standard exinguishant...
View ArticleID 2000 Suspected Break
I have just started to service an ID2000 panel but keep getting suspected break loop 1. I looked in the panel and loop 1 is linked out at the actual connections as well as powering the loop. I am...
View ArticleProtec 5200
Yes, the dreaded dinosaur. Got a call to a new client today reporting an intermittent fault. I printed out the Event History and concluded it was an 'Alarm Fault'. I printed out the Device Data to see...
View ArticleApollo xp95 beam and i/o
A quick question Went to commission a system today. Advanced mxpro 5. Loop has 2 Apollo addressable beams on it both beams commissioned and fault free but one is displaying a fault at the fap analogue...
View Articlegent silence and sound alarm events in an empty building
hello, one of our guys had a gent vigilon record in the event log several 'alarms silenced' and 'alarms sounded' events on saturday night in an unoccupied office building (so no-one was pressing...
View ArticleGent Vigi - Disablement Functions
Just after a bit of advice! I'm currently covering call out for a mate, he looks after a stadium that has a Gent Vigi consisting of 3 panels. The stadium events manager called me this afternoon and...
View Articlewhich manufacturers of CP00 fire alarm panel
Hi Guys, Its long shot ,my friend (electrician) been to site about 2 hours drive from his house to quote to install additional fire alarm call point unfortunate he lost the picture of the fire alarm...
View Article